D-Link DFE-2600 Series User Manual - Settings
Dual-Speed Stackable Hubs User’s Guide
Master Hub Setup and Management
48
The default setting for all TCP/IP variables is 0.0.0.0.
Out-of-Band Management and Console
Settings
You can use the Out-of-Band/Console Setting menu to choose whether to
use the hub’s RS-232 serial port for console management or for out-of-band
TCP/IP communication using SLIP, and to set the baud rate used for SLIP
communications.
The following fields can be set:
♦
System Restart Out-of-Band Baud Rate. This parameter deter-
mines the serial port baud rate that will be used the next time the hub
is restarted. It applies only when the serial port is being used for
out-of-band (SLIP) management; it does not apply when the port is
used as a console port. Available speeds are 1200, 2400, 9600, and
19200 bits per second.
♦
Out-of-Band Dial Up Phone Number. This information is stored
as a reference for the benefit of the system manager and does not
cause the hub to dial out.
♦
System Restart Serial Port Setting. This parameter determines
whether the serial port should be used for out-of-band (SLIP) man-
agement or for console management, starting from the next time the
hub is restarted. It can be set to either “ Console” or “ Out-of-
Band.”