Master Hub Setup and Management
59
hh:mm:ss.xx, with hh representing hours since the master hub was
turned on, mm the minutes, ss the seconds, and xx representing
100ths of a second.
♦
Group Slot (1). Shows the status of module slot 1. If there is a
module installed in slot 1, this field will display: MII, TP, FX, or
Switch as determined by the type of module installed. If there is no
module installed, the field will display “ None.”
♦
Group Slot (2). Shows the status of module slot 2. If there is a
module installed in slot 2, this field will display: MII, TP, FX, or
Switch as determined by the type of module installed. If there is no
module installed, the field will display “ None.”
♦
Group Isolate. Provides control of the hub’s current network con-
nection status and allows the system manager to manually isolate a
particular hub as needed and reconnect it later. Toggling the field to
“ Isolate” separates the hub’s data connection from the other hubs.
Toggling the field to “ Reconnect” re-establishes the connection.
See “ Segmenting Hubs” earlier in this chapter for more information.
DFE-2600 Stackable Hub - Network Monitoring : Group Configuration Menu
Group ID (1-5)
[1]
Group Serial Number:
623000B
Group Position Number:
Group Description:
DFE2624i
Group Role:
Primary Master
Group Port Capacity:
24
Group Hardware Revision:
Rev. 06
Group Master Revision:
Rev. 01
Group Status:
Up
Group Last Oper Change:
0:1:35.90
Group Slot (1):
Switch
Group Slot (2):
none
Group Isolate:
PREV GROUP
NEXT GROUP
HELP
SAVE
EXIT