FAAC E124 Manual - page 14
2
ENGLISH
6.2.2MEMORYSTORAGEOFBUS-2EASYACCESSORIES
You can add the BuS-2EASY accessories to the system at any
time, simply by memory-storing them on the board, observing
the following procedure:
Install and program the accessories using the required
address (see parag. 6.2.).
Cut power to the board.
Connect the two cables of the BuS-2EASY accessories to
the red terminal-board J3 (any polarity will do).
Power the board, taking care to first connect plug J of the
main power supply (coming from the switching feeder) and
then, connector J2 of any batteries.
Quickly press once only the SETuP (SW3) push-button,
to execute learning. Check operation of the installed
BuS-2EASY devices.
The board has memory stored the BuS-2EASY accessories.
Follow the instructions in the table below to check if the
BuS-2EASY connection is correct.
Tab.2-DescriptionofLEDDL12(RED)
ON
Safety device engaged or pulse generator
active
OFF
NO safety device engaged and NO pulse
generator active
Tab.3-DescriptionofLEDDL13(GREEN)
Steadylight
Normal activity (LED Lighted even if no
photocells)
OFF
Line BuS-2EASY short circuiting (flash every
2.5 sec.)
Fastflashing
Error detected in BuS-2EASY connection
error, repeat the acquisition procedure. If
the error is repeated, make sure that there
is not more than one accessory with the
same address in the system (also see the
accessories instructions).
.
2.
3.
4.
5.
6.2.3ADDRESSINGTHEBUS-2EASYENCODERS
Connection of the BuS-2EASY input in the control board is via
the bipolar cables which come out of the encoders.
Unlikethecaseofthephotocelldevices,the
polarity of the BUS-2EASY line connection
determineswhethertheencoderbelongsto
oneleafratherthantotheother.
This is why you must pay great attention to the indications of
the status LEDs on the body of each encoder (Fig. 26).
Below we list the functions of LEDs DL, DL2, and DL3, and their
statuses:
Tab.4-EncoderconnectionandLEDstatus
LED
ON
FLASHING
OFF
DL
Power ON and
BuS -2EASY
communicating
with board
Power ON but
BuS-2EASY not
communicating
No power to or
communication
with BuS-2EASY
DL2 Leaf encoder /
Leaf 2 encoder
DL3
Leaf not moving Pulses read while
leaf moving
Leaf not moving
DL 1 must always be lighted to guarantee correct
connection between encoder and board.
DL2 determines the leaf on which the encoder is installed.
Providing the configuration is correct, the automated
system will show: an encoder with DL2 lighted in leaf
, and an encoder with DL2 OFF in leaf 2. If there is an
incorrect connection, i.e. indicating two encoders with
the same status of the DL2 LEDs, during the learning
procedure of the BuS-2EASY accessories, the DL LEDS
of both encoders show a FLAShING status. In this situation,
refer to the configuration in TAB.4 to define which encoder
connection to rotate.
DL3 indicates, on a steady flashing beam, the reading
of the pulses while the leaf is moving. When the leaf is
motionless, DL 3 can be either lighted or OFF.
•
•
•
DL ON
DL3 OFF
DL ON
DL3 OFF
DL ON
DL ON
DL3 OFF
Leaf
Leaf 2
Leaf
Leaf 2
Fig. 26
ENCODERWIRINGFOROPERATORS700H/S800H
LEAF 1*
TWO LEDs ON
LEAF 1*
TWO LEDs ON
LEAF 2
ONE LED ON
REVERSE THE ENCODER WIRES TO EXCHANGE
BETWEENTHEENCODERASSOCIATEDWITHLEAF
1ANDTHEENCODERASSOCIATEDWITHLEAF2
ANDVICEVERSA
LEAF 2
ONE LED ON
*
LEAF1OPENSASFIRSTANDCLOSESASSECOND.
IFNOREBATEISPRESENTBETWEENLEAF1AND
2, SET LEAF DELAY TO ZERO ON THE CONTROL
BOARD.
DL2 ON
DL3 OFF
DL2 OFF
DL2 ON
DL2 OFF