FAAC E124 Manual - page 18
6
ENGLISH
rL
DECELERATION:
Adjusts deceleration space as a percentage of the
total travel of the leaves. Adjustable from
00
to
99
%.
in % steps.
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
Other more detailed programming
possibilitiesarefeasiblebyPCprogramming
(seededicatedinstructions).
30 30 30 20 20 20
St
AUTOMATEDSYSTEMSTATUS:
Exit from programming, storage of data and return to the automated system status view
00
= CLOSED
01
= OPEN
02
= Idle then “OPENS”
03
= Idle then “CLOSES”
04
= In “PAuSE”
05
= At opening stage
06
= At closing stage
07
= FAIL SAFE in progress
08
= verification of BuS-2EASY devices in progress
09
= Pre-flashing then “OPENS”
10
= Pre-flashing then “CLOSES”
11
= Opening in EMERGENCY status
12
= Closing in EMERGENCY status
Display
Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
7.2. 2
nd
LEVELPROGRAMMING
To access 2
ND
LEVEL PROGRAMMING, press push-button F and, while holding it down, press push-button +:
if you release the +key, the display shows the name of the first second level function (if the
dF
value persists, this means
that programming was effected from the PC).
if you also release the F push-button, the display shows the value of the function, which can be changed with keys + and -.
if you press the F key (and hold it down), the display shows the name of the next function; if you release it, the values is
shown and can be modified with keys + and -.
when you reach the last function, press theF push-button to exit programming, and the display resumes showing the
automated system status.
If programming via the PC with personalised password was effected, you CANNOT enter 2
nd
level
programming.
•
•
•
•
2
nd
LEVELPROGRAMMING
Display
Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
bo
MAXIMUMPOWERATTHRUST:
The motors run at maximum power for the time set
(ignoring the selected power level F and F2) during
motion thrust.
Adjustable from
00
to
06
seconds in -second steps.
Other more detailed programming
possibilitiesarefeasiblebyPCprogramming
(seededicatedinstructions).
02 02 02 02 02 02
EL
ELECTRICLOCKONLEAF2:
The board has a terminal dedicated to the connection
of an electric lock. Normally the electric lock must be
connected to leaf . If the electric lock is located on
leaf 2, adjust the parameter.
Y
= electric lock on leaf 2
no
= electric lock on leaf
no no no no no no
cd
LEAFDELAYATCLOSING:
Adjusts leaf delay at closing.
Adjustable from
00
to
60
seconds in -second steps.
00
= no delay
01
= minimum delay
60
= maximum delay
05 05 05 05 05 05