IN1-OPENA-“Opening”Command(N.O.-terminal1):
this refers to any pulse generator (e.g.: push-button) which,
by closing a contact, commands TOTALOPENING.
Toinstallseveraltotalopeningpulsegenerators,
connecttheN.O.contactsinparallel
Othermoredetailedprogrammingpossibilities
arefeasiblebyprogrammingwithaPC(see
dedicatedinstructions).
IN2-OPENB-PartialOpening”command(N.O.-terminal3):
this refers to any pulse generator (e.g.: push-button) which,
by closing a contact, commandsPARTIALOPENING.
For double leaf or single leaf systems, OPEN
Bcommandsanopeningofleaf1(motor1)
correspondingto100%oftotalopening
To install several partial opening pulse
generators, connect the N.O. contacts in
parallel
Othermoredetailedprogrammingpossibilities
arefeasiblebyprogrammingwithaPC(see
dedicatedinstructions).
Ifyouselectoneofthefollowinglogics(b,bC,
C)inputIN2automaticallybecomesCLOSE
(N.O).
5TERMINALBOARDS,CONNECTORS,INPUTSANDSIGNALS
Connection of 2 N.O. contacts in parallel
IN4 - Opening safety-devices contact (N.C. - terminal 5):
see paragraph 6..
To install several opening safety devices, connect
the N.C. contacts in series.
Othermoredetailedprogrammingpossibilities
arefeasiblebyprogrammingwithaPC(see
dedicatedinstructions).
Ifopeningsafetydevicesarenotconnected,
jumperconnectterminalsIN4andGND,ifthe
FAIL-SAFEsafetydeviceisnotactive,otherwise
jumperconnectIN4and–OUT1.
IN5-Closingsafety-devicescontact(N.C.-.terminal7):see
paragraph 6..
To install several closing safety devices, connect
the N.C. contacts in series
Othermoredetailedprogrammingpossibilities
arefeasiblebyprogrammingwithaPC(see
dedicatedinstructions).
Ifclosingsafetydevicesarenotconnected,
jumperconnectterminalsIN5andGND,ifthe
FAIL-SAFEsafetydeviceisnotactive,otherwise
jumperconnectIN5and–OUT1.
GND-(terminals2-6):Negativeforpoweringaccessories
+24-(terminal8):Positivetopowerfeedaccessories
The max. load of the accessories is 500mA,
subdividedamongterminalboardsJ4andJ7.
Tocalculatemaximumabsorption,refertothe
instructionsforindividualaccessories.
Connection of 2 NC contacts in series
IN3-STOPcontactcommand(N.C.-terminal4): this refers to
any device (e.g.: push-button ) which, by opening a contact,
can stop the motion of the automated system.
To install several STOP devices, connect the N.C.
contacts in series.
Othermoredetailedprogrammingpossibilities
arefeasiblebyprogrammingwithaPC(see
dedicatedinstructions).
Ifstopsafetydevicesarenotconnected,jumper
connecttheSTOPandGNDterminals.
5.1 TERMINALBOARDJ3–CONNECTIONTOBUS-2EASYACCESSORIES
Terminal for connection of BuS-2EASY accessories. see
par. 6.2
5.3 TERMINALBOARDSJ5,J8–OUT1ANDOUT2
The two outputs can be set in one of the functions described
in 2nd level programming (see par.7.2.). The default value is:
OuT = ALWAYS ACTIVE
OuT2 = INDICATOR LIGhT.
Maximumloadapplicableoneveryoutput:
24Vdcwith100mA.
5.2 TERMINALBOARDJ4–SIGNALSINPUTS
Fig. 9
Fig. 8