FAAC E124 Manual - page 23
2
ENGLISH
Display
Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
AS
ASSISTANCEREQUEST–CYCLESCOUNTER(coupledto
thenexttwofunctions):
Y
= When the number of cycles settable with the
following
nc
and
nd
functions is reached, this
facility pre-flashes for 8 sec. (in addition to the pre-
flashing already set with the
PF
function) before
every movement.
If,fromthePC,anassistancerequestis
set,withanumberofcyclesgreaterthan
99.990,thenexttwofunctions
nc
and
nd
willrespectivelyshow99and99.
no
= the following functions
nc
and
nd
indicate how
many cycles the system effected up to a maximum
displayable amount of 99.990.
Ifthenumberofeffectedcyclesisgreater
than99.990,thenexttwofunctions
nc
and
nd
will respectively show 99 and
99.
This function can be useful to set routine maintenance
or to check the effected work cycles.
no no no no no no
nc
CYCLEPROGRAMMING(THOUSANDS):
If
AS
=
Y
, the display indicates the number of the thou-
sands of cycles after which assistance is request-
ed (settable from
0
to
99
).
If
AS
=
no
, the display indicates the number of the
thousands of effected cycles. The displayed val-
ue updates itself as the cycles follow, interacting
with the
nd
values.
If
AS
=
no
bypressingkeys+and–for5
sec.,thecyclescounterisreset.
00 00 00 00 00 00
nd
CYCLEPROGRAMMING(TENS):
If
AS
=
Y
, the display indicates the number of tens
of cycles after which assistance is requested
(settable from
0
to
99
).
If
AS
=
no
, the display indicates the number of the tens
of effected cycles. The displayed value updates
itself as the cycles follow, interacting with the
nc
values.
Example:Ifthesystemhasperformed11.218,
nc
=11and
nd
=21willbeshown
00 00 00 00 00 00
M1
MOTOR1DRIVE(dead-manfunction)
Holddownpush-button+opening
oP
Holddownpush-button-closing
cL
-- -- -- -- -- --
M2
MOTOR2DRIVE(dead-manfunction)
Holddownpush-button+opening
oP
Holddownpush-button-closing
cL
-- -- -- -- -- --
St
AUTOMATEDSYSTEMSTATUS:
Exit from programming, storage of data and return to the automated system status view.
00
= CLOSED
01
= OPEN
02
= Idle then “OPENS”
03
= Idle then “CLOSES”
04
= In “PAuSE”
05
= At opening stage
06
= At closing stage
07
= FAIL SAFE in progress
08
= verification of BuS-2EASY devices in progress
09
= Pre-flashing then “OPENS”
10
= Pre-flashing then “CLOSES”
11
= Opening in EMERGENCY status
12
= Closing in EMERGENCY status