FAAC E124 Manual - page 19
7
ENGLISH
od
LLEAFDELAYATOPENING:
Opening of leaf 2 is delayed with respect to leaf ,
avoiding thus interferences between the leaves.
Y
= active
no
= excluded
Y
Y
Y
Y
Y
Y
t
WORKTIME(time-out):
We advise you to set a value longer than the time re-
quired by the gate to open and close completely.
Can be adjusted from
01
to
59
sec. in second steps.
Next, the viewing changes in minutes and ten seconds
(separated by a dot) and time is adjusted in 0 second
steps, up to the maximum value of
9.5
minutes.
4.1 4.1 4.1 4.1 4.1 4.1
r8
SPACEOFTRAVELSTOPSEARCH:
The set level, from
01
to
50
, adjusts the space of the
search for the travel stop referred to total travel of the
leaves. For the default values
0-1-2-4
, the value
50
corresponds to 40% of total travel, whereas for the
default values
3-5
, the value
50
corresponds to 20%
of total travel.
Leaves do not reverse in the space of the search for the
travel stop in the event of an obstacle.
20 20 20 08 20 08
cS
FINALCLOSINGTHRUST:
The motors are run at maximum power to facilitate cou-
pling with the electric lock (over pushing stroke).
Y
= active
no
= excluded
Othermoredetailedprogrammingpos-
sibilitiesarefeasiblebyprogrammingwith
aPC(seededicatedinstructions).
no no no no no no
rS
REVERSINGSTROKEATOPENING:
When the gate is closed before opening, the motors
push to close to facilitate uncoupling the electric clock
(reversing stroke).
Y
= active
no
= excluded
Othermoredetailedprogrammingpos-
sibilitiesarefeasiblebyprogrammingwith
aPC(seededicatedinstructions).
no no no no no no
SF
SOFTTOUCH:
After touching the travel stop point, the leaves reverse
and then rest gently.
Y
= active
no
= excluded
This function can be useful to respect
the impact curve specified by current
standards.
Other more detailed programming
possibilitiesarefeasiblebyPCprogramming
(seededicatedinstructions).
no no no no no no
PF
PRE-FLASHING:
Enables you to select 5 types of pre-flashings of 3 sec.
duration.
no
= no pre-flashing
.
OC
= pre-flashing before every movement.
CL
= pre-flashing before a closing motion.
OP
= pre-flashing before an opening motion.
PA
= pre-flashing at end of pause only
Othermoredetailedprogrammingpos-
sibilitiesarefeasiblebyprogrammingwith
aPC(seededicatedinstructions).
no no no no no no
Display
Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5