FAAC E124 Manual - page 9
7
ENGLISH
5.4TERMINALBOARDJ6–OPENINGANDCLOSINGTRAVELLIMITDEVICE
Terminal board for connection of the opening (FCA and FCA2)
and closing (FCC and FCC2) travel limit device.
The travel limit contacts FCC1, FCA1, FCC2
andFCA2areallNCcontacts.See2ndlevel
programming for the various configurations
applicabletothetravellimitinputs.
Iftheyarenotused,donotjumperconnectthecontacts
ofthelimitswitchesFCC1,FCA1,FCC2,FCA2
5.5 TERMINALBOARDSJ7-ENCODERS
Encoders with an open collector signal referred to earth (e.g.
Gatecoder) can be connected to detect the leaf’s angular
position. For connections, see fig. 0.
Theconfigurationindicatedinthedrawingis
themaximumone.Only1Gatecodercanbe
used.Inthiscase,theunusedinputsdonot
havetobejumperconnectedtoearth
Thedefaultobstacledetectionandstoppoint
timesare2and4secondsrespectively.
RED
RED
BLACK
BLACK
WHITE
WHITE
5.6 TERMINALBOARDJ9–FLASHINGLAMP
Output for 24Vdc flashing lamp
Maximumapplicableload:24Vdc-15W
5.7 TERMINALBOARDJ10–ELECTRICLOCK
Output for 2V ac or 24V dc electric lock
5.8 TERMINALBOARDJ11,J12-MOTORS
J11(MOT1): Connection of motor connected to leaf , i.e. the
leaf which opens first during an opening operation.
J12(MOT2)
: Connection of the motor connected to leaf 2,
i.e. the leaf which opens second.
If only one motor is connected, it must be
connectedtoterminalJ11(MOT1).
If, during the first movement of the SETUP
procedure,theleavesopeninsteadofclosing,
themotorconnectioncablesmustbechanged
over.
5.9 CONNECTOR J1 - PRIMARY POWER FEED FROM
230/115VMAINS
J1: Select the correct power feed, by turning the power switching
selector to its correct position (Default 230 Vac.)
To ensure correct operation, the switching
feeder must be connected to the earth
conductorinthesystem.Installanadequate
differential thermal breaker upstream of the
system.
Fig. 0
115Vac
Fig.
230Vac