FAAC E124 Manual - page 27
25
ENGLISH
11 AUTOMATEDSYSTEMTEST
When you have finished installation and programming, check
if the system is operating correctly. In particular check if the
safety devices intervene correctly, and make sure that the
system satisfies current safety regulations. Close the cover in
its seat with a seal.
Next, tighten the four supplied screws to guarantee the degree
of protection against external agents (Fig. 33).
10.2TIMELEARNING-SETUP
The opening and closing time is determined by a time learning
procedure (SETuP).
Thisprocedureisthesameforallselectable
defaults.
When the encoders (J3 or J7) are connected to the relevant
inputs, the board automatically recognises the presence of
these accessories.
By powering up the board if a SETUP was
neverexecuted,oriftheboardrequestsit,
theletters
S0
togetherwiththeSETUP(DL18)
LEDflashonthedisplay,toindicatethatthe
SETUPmustbeexecuted.
Beforeperformingtheset-upphase,selectthe
typeofmotorsused.
To execute time learning, follow the steps below:
Taketheleavestohalfwaytheirtravel(veryimportant
forasuccessfulSETUP).
hold down the SETuP (SW3) push-button, until the SETuP
(DL8) LED goes OFF and leaf 2 (if present) begins the
slowed down closing movement, stopping when it reaches
the mechanical stop point. At this stage,
S1
flashes on the
display (setup: FIRST CLOSuRE LEAF 2)
Leaf starts the slowed down closing movement, stopping
when it reaches the closing mechanical stop. At this stage,
S2
flashes on the display (setup: FIRST CLOSuRE LEAF )
Leaf begins the slowed down opening movement,
followed by leaf 2 (if present) also slowed down. At this
stage,
S4
flashes on the display (setup: OPEN)
When the opening mechanical stop point is reached, both
leaves stop and leaf 2 (if present) automatically restarts
to close at full speed, followed by leaf . At this stage,
S5
flashes on the display (setup: FAST CLOSE).
When the closing mechanical stop point is reached, both
leaves stop and leaf restarts to open automatically at
full speed followed by leaf 2 (if present). At this stage,
S6
flashes on the display (setup: FAST OPEN).
If an automatic logic was selected, the board counts the
set pause and automatically closes the gate. Otherwise,
give an OPEN pulse to close the gate.
1.
2.
3.
4.
5.
6.
7.
12 ALARMANDERRORSIGNALS
If alarms (conditions not prejudicing gate operation) or errors
(conditions preventing the gate from operating), the display
shows the number referring to the condition.
Thesesignalswilldisappearduringthefollowing
cycleonlyifthecauseisremoved.
12.1ALARMS
When an ALARM occurs, LED DL20 starts to
flash.Ifyousimultaneouslypresskeys+and
–thedisplaywillshowthenumberofthefault
inprogress
All the alarms shown on the display are indicated in Tab.8.
Tab.8-Alarms
2 0
Obstacle on MOTOR
2 1
Obstacle on MOTOR 2
2 2
MOTOR current limited
2 3
MOTOR 2 current limited
2 4
LAMP output short circuited
2 5
LOCK output short circuited
3 0
radio codes XF memory full
3 5
Timer function active
4 0
Service request
4 5
Battery operation
5 0
hOLD CLOSE function in operation (activated by
PC)
12.2ERRORS
WhenanERRORoccurs,LEDDL20goesON
atsteadybeam.Ifyousimultaneouslypress
keys+and–thedisplaywillshowthenumber
ofthefaultinprogress
All the errors shown on the display are indicated in Tab.9.
Tab.9-Errors
0 1
Board failure
0 2
Thermal protection active (wait for reset)
0 3
Motor failure
0 4
Motor 2 failue
0 8
BuS2EASY device error
1 0
Motor limit switch error
1 1
Motor 2 limit switch error
1 5
Time-out elapsed
1 7
Motor encoder faulty
1 8
Motor 2 encoder faulty
1 9
Incorrect memory data
Fig. 33
WhentheSETUPprocedurehasbeenstarted,
iftheleavesatpoint2and3openinsteadof
closing,themotorpowersupplycablesmust
bechangedover.