Gardsman CTC-1131 Installation, Programming, Operating - page 15
13
Delay period when Home Arming.
E x i t S n d O n
E x i t S n d O f f
Exit Snd On (Exit sound On) is set as
factory default.
2.3.17.H.Entry Sound(Home Entry
Sound)
This is for you to decide whether the Control
Panel will sound short beeps during the Entry
Delay Period when Home Arming.
E n t r y S n d O n
E n t r y S n d O f f
Entry Snd On (Entry Sound On) is set as
factory default.
2.3.18.18. Siren Delay
This is for you to decide how long should the
Control Panel suppress all audible alarms after
a Burglar alarm is reported. Options are OFF
and 1-min delay to 10-min delay in increments
of 1 minute
O f f
1 M i n .
2 M i n .
3 M i n .
4 M i n .
to
1 0 M i n .
Off is set as factory default.
2.3.19.Final Door
Turn on and off the Final Door Set Option.
F i n a l D o o r O f f
F i n a l D o o r O n
FinalDoor On (Final Door Set Option On)
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
To activate Final Door properly, you
must first program the accessory for
Entry. When Final Door Arming is
programmed, the Control Panel will
arm the system after the entry door is
closed and interrupt the countdown.
For more description of this feature,
please refer to Sec. II Away (Alarm
On) Mode of Operation.
2.3.20.Remote Controller Entry
Enable (RC Ent E)
Turn on and off the Remote Controller disarm
function.
R C E n t E O f f
R C E n t E O n
Remote Controller Entry Enable On is
set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
When the Remote Controller Entry
Enable is set to Off it will not be
possible to disarm the Control Panel
when the system is fully armed unless
an entry point device is activated first.
This feature is used to ensure that the
system cannot be disarmed with a
stolen
Remote
Control
without
unlocking a door first.
When the Remote Controller Entry
Enable is set to On, the Remote
Controller can Arm and Disarm the
Control Panel as normal without
activating an entry point first.
2.3.21.Mobility Check (Mobility
CHK.)
This is to disable or enable the Mobility Timer
with selected countdown period. Options
available are Disable, 4 hours, 8 hours and
12 hours.
If the Mobility Timer is enabled, it will count
down the pre-programmed time length. When
the timer times out without being reset, a
Medical Alarm will be reported to the
Emergency phone numbers..
D i s a b l e
4 H r s V
Disable is set as factory default.