Gardsman CTC-1131 Installation, Programming, Operating - 3.3. Forced Arming
24
using the Remote controller (Optional).
3.2.2. Stopping the Exit Delay
The Exit Delay can be stopped by disarming
the system.
Step 1. Press
Step 2. The screen will ask you to enter the
PIN code. In addition, the counting
down Exit Delay is displayed on the
left side of the 2
nd
line.
Step 3. Enter your PIN code and thenpress
OK. Alarm Off will be displayed on
the screen and the system returns to
Disarmed mode.
<
<
N
N
O
O
T
T
E
E
>
>
The Exit Delay can also be stopped by
pressing the Disarm button on the
Remote Controller (Optional).
If the Exit Delay period times out
before the code can be entered, the
system will arm.
3.2.3. Extend the Exit Delay
During the Exit Delay period, the delay time
can be extended by pressing the ARM button
on the Remote Controller (Optional). Each
time the ARM button is pressed, the delay time
starts counting from the beginning.
<
<
N
N
O
O
T
T
E
E
>
>
While you arm the system, if a Door
Contact or PIR sensor has been
triggered (eg. Door is open), arming is
also prohibited. To arm the system,
please see the section Forced
Arming below.
3.3. Forced Arming
While you try to arm the system by
entering the PIN Code, if there is any fault
situation has occurred before, the display
will show.
F a u l t D s p
A w a y A r m
If you move the cursor to Away Arm
position and then press OK, the Control
Panel will sound a ding-done warning
sound to indicate arming is prohibited, and
the message Fault DSP is displayed in
the middle of the top display row and
alternates at 2-second intervals with
individual fault events.
<
<
N
N
O
O
T
T
E
E
>
>
In the same situation, if you arm the
system by pressing the Arm button on
the Remote Controller, the Control
Panel will response in the manner as
described above and the arming is
also prohibited.
At this moment, you can first rectify all of
the problems and then clear the Fault
display (Please see section XI In a Fault
Situation), and then afterwards you can
arm the system.
However, if you want to put the system
into Arm mode with the fault situation
persisting, it is still possible by following
the steps below to execute Forced
Arming.
Step 1. Enter your PIN Code and press OK, a
prompt message will be displayed.
F o r c e A r m
( O k ? )
Step 2. Press OK to double confirm.
Step 3. The Exit Delay counting down screen
is displayed as in above section.
Step 4. When the Exit Delay time is up, the
Control Panel will sound a long beep.
The Alarm On will display on the
screen and the system is in Arm mode.
<
<
N
N
O
O
T
T
E
E
>
>
Any time pressing
followed by PIN
Code and OK, the screen returns to
Alarm Off
The Fault DSP screen has a time-out
of 5 minutes. It will automatically exit
and return to Alarm Off screen
afterwards.
If a sensor is by-passed (Please see
section Partial Arm mode, the fault
condition of that sensor will not be
checked.
If a sensor tampered or out-of-order
occurs, you can temporarily by-pass it
or permanently remove it.