Gardsman CTC-1131 Installation, Programming, Operating - page 33
31
If the Control Panel can’t receive the
signals transmitted from an individual
sensor for a supervisory period, that is set
on Page 14 / 24. Supervision, sensor
out-of-order fault event will be detected.
3.12.1. Fault Message Display
When any fault situation persists, the
Control Panel will respond as below when
it is in Disarmed mode:
The Yellow LED will light to indicated
the fault condition
The LCD will display the type of fault
and the source of the fault in the
Fault Display section of the User
Menu.
A warning beep will sound at every
30 seconds.
If a fault condition is detected while
the system is in full arm mode, the
fault event display will not be
generated
until
the
system
is
disarmed.
3.12.2. Clearing Fault Message
Display
The Yellow LED will turn off automatically
once all of faulty conditions are restored, or
any faul
ty devices are removed. It can’t be
cleared manually.
On the contrary, the fault message display
retains even though the faulty conditions
have been restored.
The fault message can only be cleared
manually after the fault condition has been
rectified.
3.12.3. V iewing/ Clearing the Fault
Message
To check what the fault condition is,
Step 1. When the system is in Disarmed mode.
Enter your PIN Code followed by OK.
Step 2. The screen will display
F a u l t D s p
A w a y A r m
and the cursor stays at Fault Dsp
Step 3. Press OK to select Fault Dsp
Step 4. All the fault events are listed. Use
,key to move the cursor
downwards or upwards. The screen
is also scrolled down or up
respectively.
Step 5. After viewing all the fault events, press
key, a prompt message is displayed.
C l e a r F a u l t
d i s p l a y ( O K ? )
Step 6. Press OK, then the fault event, which
the fault condition has been rectified,
will be cleared and the screen returns
to Alarm off.
<
<
N
N
O
O
T
T
E
E
>
>
In Step 6, if key is pressed, the
screen returns to Alarm off, the
Yellow LED stays on, the Control
Panel keeps sounding a short beep
every 30 seconds, and the fault event
display retains.
If the fault condition has not been
rectified, the fault event display will not
be cleared. It will come on again
while you try to arm the system and
the faulty condition inhibits the system
from being armed, then the fault
message will be displayed again. The
fault event display can be cleared only
after the fault condition has been
rectified.
Even when the fault messgae is
cleared, the fault event is still retained
in the Log.
3.12.4. Fault Event Response
When a fault condition is detected, in
addition to the fault display, the Control
Panel
will
also
respond
separately
according to the nature of the fault event.