6. TROUBLESHOOTING
This section provides information to assist troubleshooting if problems occur after completing the
installation. Devices connected to the GPS 500W/GNS 530W can be useful for determining whether the
500W Series unit is functioning properly or if there are problems with the installation.
6.1 Troubleshooting
Procedure
Table 6-1. Troubleshooting Guide
Problem Possible
Cause
Solution
The 500W Series
unit does not power
on.
•
The unit is not getting power to
the main connector P5001.
•
Make sure power is connected to the
main 78-pin connector P5001, pins
19 and 20 and ground to P5001, pins
77 and 78. Check circuit breakers
and main avionics switch.
•
Check the GPS antenna connections.
Make sure the aircraft is clear of
hangars, buildings, trees, etc.
The 500W Series
unit does not
compute a position.
•
Not receiving signals.
•
Wait 20 minutes for unit to complete
cycle.
GPS signal levels
drop when avionics
are turned on.
•
Noise interference from other
avionics.
•
Turn all avionics off, then turn on
each piece one at a time to isolate the
source of the interference. Route GPS
cable and locate GPS antenna away
from sources of interference.
•
Improper antenna installation
or coax routing.
•
Check GPS antenna installation,
connections, and cable routing. The
GPS antenna must be mounted on the
top of the aircraft.
•
Antenna shaded from satellites.
•
Make sure the aircraft is clear of
hangars, buildings, trees, etc.
The GPS signal
levels are very low.
•
RF interference at 1575.42
MHz from VHF COM.
•
Move GPS antenna further from the
COM antenna. Add a 1575.42 MHz
notch filter in COM coax. Fix or
replace the COM. Disconnect the
ELT antenna coax to check for
possible re-radiation.
•
The PTT input is not being
pulled low.
•
Check that the PTT (mic key) input is
pulled low for transmit.
•
No transmit power to the
COM.
•
Make sure power input is connected
to the COM 25-pin connector P5002
11 and 12 and ground to P5002 21
and 22.
The 500W Series
unit does not
transmit.
•
The input voltage is too low.
•
Increase input supply voltage to
>12VDC. (>24VDC for 530AW