1.4.2 General
Specifications
Operating Temperature Range
-20
°
C to +55
°
C. For more details see Environmental
Qualification Form on the Dealers Only page on
www.garmin.com. See Appendix A for part numbers.
Humidity
95% non-condensing
Altitude Range
-1,500 ft to 50,000 ft
Input Power Requirements
Input Voltage Range - All Units (Main
Connector)
10 to 33.2 VDC
Input Voltage Range (COM Connector)
GNS 530W
11 to 33 VDC
Input Voltage Range (COM Connector)
GNS 530AW
24.1 to 33 VDC
GPS 500W (Main Connector)
800 mA @ 28 VDC (maximum)
1.6 A @ 14 VDC (maximum)
GNS 530W, GNS530AW (Main Connector) 1.4 A @ 28 VDC (maximum)
3.0 A @ 14 VDC (maximum)
GNS 530W (COM Connector)
15 mA @ 28 VDC (receive)
3.0 A @ 28 VDC (transmit)
15 mA @ 14 VDC (receive)
6.0 A @ 14 VDC (transmit)
GNS 530AW (COM Connector)
15 mA @ 28 VDC (receive)
3.0 A @ 28 VDC (transmit)
Superflag Power Requirements
500 mA maximum per superflag output
Environmental Testing
See Environmental Qualification Form on the Dealers
Only page on www.garmin.com. See Appendix A for
part numbers.
The display on the 500W Series unit is a sunlight readable LCD display.
Display Size
5.0” diagonal
Active Area
4.02” (W) x 2.95” (H)
Resolution
320 x 234 pixels
Viewing Angle
(with a 5:1 contrast ratio, min)
Left/Right:
Up:
Down:
60
°
35
°
60
°
Viewing Distance
36 inches maximum