Jacobsen Eclipse 322 Repair Manual - page 177
ELECTRICAL
4222983 Second Edition
4-103
4
DTC: Check Left Actuator
Actuator did not reach position within 6 seconds.
DTC: Check Center Actuator
Actuator did not reach position within 6 seconds.
DTC: Check Right Actuator
Actuator did not reach position within 6 seconds.
Probable Cause
Remedy
Lift arm mechanical binding.
Check lift arm pivot points for binding.
Up-stop adjustments.
Check up-stop adjustments.
Incorrect cut position.
Calibrate actuator.
Faulty connections.
Check connections; make sure connections are dry, clean of corrosion and tight.
Low 48V system voltage.
Check system voltage; voltage must be in the range of 43—60 VDC.
Faulty lift actuator.
Substitute the lift actuator with a known good lift actuator. If system now works, re-install
old component to verify fault returns.
Probable Cause
Remedy
Lift arm mechanical binding.
Check lift arm pivot points for binding.
Up-stop adjustments.
Check up-stop adjustments.
Incorrect cut position.
Calibrate actuator.
Faulty connections.
Check connections; make sure connections are dry, clean of corrosion and tight.
Low 48V system voltage.
Check system voltage; voltage must be in the range of 43—60 VDC.
Faulty lift actuator.
Substitute the lift actuator with a known good lift actuator. If system now works, re-install
old component to verify fault returns.
Probable Cause
Remedy
Lift arm mechanical binding.
Check lift arm pivot points for binding.
Up-stop adjustments.
Check up-stop adjustments.
Incorrect cut position.
Calibrate actuator.
Faulty connections.
Check connections; make sure connections are dry, clean of corrosion and tight.
Low 48V system voltage.
Check system voltage; voltage must be in the range of 43—60 VDC.
Faulty lift actuator.
Substitute the lift actuator with a known good lift actuator.