LaCie 12big Rack Fibre 8 Quick Install Manual - page 10
LaCie 12big Rack Fibre and expansion
Completing the Installation
Quick Install Guide
page 10
Enter a “new” password and confirm the new password.
6.
Click the Configure button.
If you have additional Uninitialized Systems, select the next
7.
MAC address and choose the appropriate settings from the
previous steps.
Once you have completed configuring all the Uninitialized
Systems and have clicked the Configure button, the wizard
will display a popup message indicating all systems have
been configured. It will then re-scan for Uninitialized Systems
and if none are found, you will be taken to the Initialized
Systems screen.
However, if you wish to only configure one Unitialized
System, the one you are configuring, and choose not
to configure any other discovered Uninitialized System,
click the Next button. You will receive a prompt that you
have not configured all systems. Click the YES button to
continue or NO to cancel and return to the Uninitialized
Systems screen.
Select the MAC address of the Initialized System you
8.
wish to start and click the Launch button. StorView will
start up.
Your web browser will open with a login screen. Enter
9.
the login name and password then click OK. StorView
will open in the browser at the Main screen.
login: admin
10.
password: password
iMPoRTanT noTe:
If you are finished starting up Embedded
Modules, be sure to select the active Embedded StorView Setup
Wizard window in the Windows Task Bar and click the Close button.
Figure 15: Uninitialized Embedded Systems
The embedded module is identified by its MAC and IP ad-
dress. It may be more helpful during setup to configure one
embedded module at a time. You will find the MAC and IP
address by accessing the VT-100 RAID Configuration Utility,
selecting Diagnostics then choosing StorView Embedded Module
Support. Select Enter StorView Embedded Module Menu Mode
and selecting View Network Settings.
Setting up the Embedded StorView Module:
Microsoft Windows
Insert the Software and Manuals Disc into your CD disk.
1.
The autorun program will automatically start the
navigation menu.
Click the
2.
Embedded StorView Setup Wizard link to begin
the configuration.
You are presented with a “Welcome” screen and
3.
instructions to proceed. Review the information.
Click the
4.
Next button. The program will begin searching
for Embedded StorView Modules.
Those Embedded Modules with their default password
intact will be displayed with their MAC address in an
Uninitialized Systems list window.
From the “Uninitialized Systems” screen, select the MAC
5.
address of the Embedded Module you wish to configure.
If you wish to use a DHCP server to assign your IP ad-
dress, click the check box Use DHCP.
If you wish to manually configure your network setting,
enter the correct information in the appropriate fields.
Figure 16: Initialized Embedded Systems