• Each power supply in each enclosure has a ground
leakage current of 1.8 mA max. at 60 Hz, 264V. The
design of the electrical distribution system must take into
consideration the total ground leakage current from all
supplies in all the enclosures. The rack may require labeling
with “HIGH LEAKAGE CURRENT. Ground (earth) connection
is essential before connecting a supply.”
• The rack when configured with the enclosures must meet
the safety requirements of UL 60950-1 and IEC 60950-1/
EN60950-1.
Battery Disposal
1.4.
cauTion:
There is a danger of explosion if the RAID
Controller battery is disposed of improperly. Dispose of used
batteries in accordance with the manufacturer’s instructions and
national regulations.
Power Supply
1.5.
WaRninG:
Do not remove the covers from the Power
Supplies. Danger of electric shock inside. Return them to your
supplier for replacement.
cauTion:
If this equipment is used in a manner not specified
by the manufacturer, the protection provided by the equipment
may be impaired.
ESD Precaution
1.6.
WaRninG:
Ensure that you have installed and checked a
suitable anti-static wrist or ankle strap and observe all
conventional ESD precautions when handling modules and
components. Avoid contact with backplane components and
module connectors, etc. ESD damage is not covered by warranty.
SFP Optical Transceiver
1.7.
Precaution
iMPoRTanT noTe:
Class 1 Laser Product. The optical SFP
transceiver modules must be a UL (or other North American
NRTL) RECOGNIZED COMPONENT, and must be approved
by TUV (or other European Product Safety test house) and
the laser in the module must comply with Laser Class 1, US
21 CFR (J) and EN 60825-1. If optical modules are to be
provided and installed by the end user, they must also comply
with the standards listed above.
iMPoRTanT noTe:
The optical modules provided and
installed by the end user must be a UL (or other North America
NRTL) RECOGNIZED COMPONENT and must be approved by
TUV (or other European product safety test house), and the laser
in the module must comply with Laser Class 1, US 21 CFR (J)
and EN 60825-1).
cauTion:
The RJ45 socket on the RAID Controller is for
Ethernet connection only and must not be connected to a
telecommunications network.