Lantech LGS-2300-RPS User Manual - page 74
66
or
no rate-limit
output-mode
mode
rate-limit.
Use the no form of this
command to disable output rate
limit.
switch (config-if)#
rate-limit output-mode
switch (config-if)#
no rate-limit output-mode
rate-limit
output-rate
[value]
Interface
configuration
mode
Set rate-limit output rate
value.
Range is 1~3130 for 312Kbps
unit on the port.
Output rate limit must be
between 1~3130
Disable switch (config)#interface
gigaethernet 1
switch (config-if)#
rate-limit output-rate 1000
shutdown
or
no shutdown
Interface
configuration
mode
Use the shutdown
Interface configuration
command to disable the port.
Use the no shutdown form of
this command to enable the
port.
Enable switch (config)#interface
gigaethernet 1
switch(config-if)#
shutdown
switch(config-if)#
no shutdown
show interfaces
status
[gigaethernet|port-
channel|vlan]
[if-num]
Privileged
EXEC
Show interface configuration
status and configuration.
switch #
show interfaces status
gigaethernet 1
or
switch #
show interfaces status port-
channel 1
or
switch #
show interfaces status vlan 1
show interfaces
counters
[gigaethernet|port-
channel] [if-num]
Privileged
EXEC
Show interface statistic
counter.
switch #
show interfaces counters
gigaethernet 1
or
switch #
show interfaces counters
port-channel 1
35B
Mac / Filter Table Commands Set
Lantech
Commands
Command
Level
Description
Default
Example
mac-address-table
Global
Use the mactbl aging-time
300 secs (Enable)