Qlogic 3200 Series User Manual - page 120
2–Configuring NIC
NIC TroubleShooting/Diagnostics
2-74
SN0054671-00 B
Running Linux User Diagnostics
Linux user diagnostics include QConvergeConsole diagnostics and ethtool
diagnostics.
QConvergeConsole Diagnostics
QConvergeConsole CLI-based diagnostics include the following commands:
To enable or disable the port beacon, issue the following command:
qaucli -pr nic -beacon [cna_port_inst]
To run an internal loopback test, issue the following command:
qaucli -pr nic -intloopback
cna_port_inst
>
tests_num
>
on_error
>
where
tests_num
is the number of tests (1–65535) and
on_error
is either
0=Ignore
or
1=Abort
To perform a Flash test, issue the following command:
qaucli -pr nic testflash [cna_port_inst]
To perform a hardware test, issue the following command:
qaucli -pr nic -testhw [cna_port_inst]
To perform an interrupt test, issue the following command:
qaucli -pr nic -testinterrupt [cna_port_inst]
To perform a link test, issue the following command:
qaucli -pr nic -testlink [cna_port_inst]
To perform a register test, issue the following command:
qaucli -pr nic -testregister [cna_port_inst]
NOTE:
Information on installing and starting the GUI version of QLogic's
QConvergeConsole utility is provided in the
QConvergeConsole User's
Guide
. All procedural information for that utility is covered in the
QConvergeConsole Help System
.