Santa Fe Pellet Insert
Mark area of
floor to cut
Starter hole
Use 2 x 4 from insert
packaging to support insert
D. Installation into a Factory-Built Fireplace
Thefollowingmodificationsarepermissible:
• Removalofdamperorlockedinopenposition
• Removalofsmokeshelforbaffle
• Removalofembercatches
• Removaloffiregrate
• Removalofviewscreen/curtain
• Removalofdoors
• Removaloffactory-builtfireplacefloor
• E
xternaltrimpieceswhichdonotaffecttheoperationof
thefireplacemayberemovedprovidingtheycanbestored
onorwithinthefireplaceforreassemblyiftheinsertis
removed.
•
The permanent metal warning label provided must be
attached to the back of the fireplace, with screws or
nails,statingthatthefireplacemayhavebeenalteredto
accommodatetheinsert,andmustbereturnedtooriginal
conditionforuseasaconventionalfireplace.
Figure 10.1
Figure 10.2. Measure and mark the metal
floorforcutting.Withadrill,makeastarter
holeineachcorner.
Figure 10.3.Usingasaws-all,cutoutthe
floor.
Figure 10.4. If the floor is made of thin
metal,werecommendusingthe2x4from
the insert packaging to support the insert.
The2x4mayneedtobecuttotheappro-
priatesize.
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Heath & Home Technologies
250-2061
5.5 in. width x 2 in. height
NON. ANOD. ALUM BLACK LETTERS ON SILVER
with 1/8 in. holes on both sides.
Black letters
Figure 10.1
•
Ifthehearthextensionislowerthanthefireplaceopening,
theportionoftheinsertextendingontothehearthmustbe
supported.
•
Manufacturer designed adjustable support kit can be
orderedfromyourdealer.
NOTE: Refer to chimney liner manufacturer for recom-
mendations on supporting the liner. Installation
into fireplaces without a permit will void the listing.•
• The firebrick (refractory), glass doors, screen rails,
screenmeshandloggratescanberemovedfromafac-
tory-builtfireboxinordertogainminimuminsertopen-
ingrequirements.
• Anysmokeshelves,shieldsandbafflesmayberemoved
fromafactory-builtfireboxifattachedwithmechanical
fasteners.
• The metal floor of the factory-built firebox may be
removed to facilitate the installation of the insert only
whena1inch(25mm)airspaceisprovidedbetweenthe
insertandthefloorofouterwrap.
Thefollowingisonlyoneexampleastherearemanydiffer-
entmodelsoffactory-builtfireplaces.
NOTE: This example is for reference only. Any modifica-
tions must not compromise the structural integrity
or reduce the protection for combustible materials.