Quadra-Fire SANTAFEI-MBK Installation Manual - page 12
12
7019-230G
June 5, 2017
Santa Fe Pellet Insert
4
Vent Information
A. Venting Termination Minimum Requirements
J or K
X
V
M
I
H
A
V
G
B
V
V
A
B
V
F V
C
B
B
E
L
V
D
V
Electrical
Service
V
N
V
N
V
N
N
V
Inside Corner
FIXED
CLOSED
OPEN
OPEN
FIXED
CLOSED
V
X
G
G
Termination Cap
Air Supply Inlet
Gas Meter
Restricted Area
O
P
Figure 12.1
A
12in.
AboveFinishGrade(thegradesurface
mustbeanon-combustiblematerial
B
12in.
48in.noOAK
Opendoororwindow:belowortotheside
B
12in.
Opendoororwindow:above
C
6in.
Permanentlyclosedwindow:above,below
ortotheside
D
18in.
36in.noOAK
Verticalclearancetoaventilatedsoffit
locatedabovetheterminalwithinahori-
zontaldistanceof2ftfromthecenter-line
oftheterminal
E
12in.
Clearancetounventilatedsoffit
F
12in.
Clearancetooutsidecorner
G
12in.
Clearancetoinsidecorner
H
36in.
Abovegasmeter/regulatormeasuredfrom
horizontalcenter-lineofregulator
I
36in.USA
72in.Canada
Clearancetoserviceregulatorventoutlet
J
12in.
48in.noOAK
Clearancetonon-mechanicalairsupply
inlettothebuildingorthecombustionsair
inlettoanyotherappliance
K
10fthorizontal
3ftvertical
Clearancetomechanicalairsupply
L
7ft.
Abovepavedsidewalk,paveddriveway
locatedon
publicproperty
M
12in.
Underanopenveranda,porch,deckor
balcony
N
SeeNote
below*
Electricservice:above,belowortothe
side(locationmustnotobstructorinterfere
withaccess)
O
24in.
Adjacentbuilding,fencesandprotruding
partsofthestructure
P
12in.
Clearanceaboverooflineforvertical
terminations
All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below.
24in.
Abovegrass,topofplants,woodoranyothercom-
bustible
12in.
36in.noOAK
Clearancefromanyforcedairintakeofotherappli-
ance
12in.
Clearancehorizontallyfromcombustiblewall
15in.
Venteddirectlythroughawall,minimumlengthof
horizontalpipe
6in.horizontal
12in.vertical
Minimumhorizontalorverticalterminationsmust
protrudefromwall
*NOTE: Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdic-
tion.Localcodesorregulationsmayrequiredifferentclearances.
NOTICE:
Do NOT Terminate Vent:
• Inanylocationthatwillallowfluegasesorsootfromen-
teringorstainingthebuilding
• Inanylocationwhichcouldcreateanuisanceorhazard
• Inanyenclosedorsemi-enclosedareasuchasacarport,
garage,attic,crawlspace,underasundeckorporch,
narrowwalkway
• Closely fenced area, or any location that can build up
a concentration of fumes such as a stairwell, covered
breezeway,etc.
NOTICE:
Termination must exhaust above air inlet elevation.
• Itisrecommendedthatatleast60inches(1.52m)ofvertical
pipebeinstalledwhenapplianceisventeddirectlythrougha
wall.Thiswillcreateanaturaldraft,whichwillhelpprevent
thepossibilityofsmokeorodorventingintothehomeduring
apoweroutage.
• Itwillalsokeepexhaustfromcausinganuisanceorhazard
byexposingpeopleorshrubstohightemperatures.
• Thesafestandpreferredventingmethodistoextendthevent
verticallythroughtherooforabovetheroof.