TallyGenicom 6306 Maintenance Manual - page 21
Chapter 1. Technical Overview
15
1.10.2 Dimensions
6306 and 6312
Table Top
Pedestal
Height
13.0 in.
39.7 in.
Width
28.3 in.
28.3 in.
Depth
14.4 in.
23.4 in.
Depth w/ paper exit guide assembly
23/4 in.
29.4 in.
Depth w/paper tray
--
29.5 in.
1.10.3 Environment
1.10.3.1 Operating
6306 / 6312
Temperature
10
C to 40C (50F to 104F)
Humidity
10 to 90% non-condensing with a maximum wet bulb temperature of 28
C
(82
F) and minimum dew point of 2C (36F)
Altitude
To 8,000 ft.
Thermal Shock
16
C (29F) per minute
1.10.3.2 Non-operating (as packaged by TallyGenicom)
6306 / 6312
Temperature
-40
C to 66C (-40F to 151F)
Humidity
5 to 95% non-condensing
Altitude
To 10,000 ft.
Thermal Shock
16
C (29F) per minute
Mechanical Shock
and Vibration
The unit complies with ISTA Programs 1 and 2 as packaged by Tally for
shipment
The printer must be allowed to reach room temperature before operating. Three hours out of the
shipping container is usually enough time for stabilization.
1.10.4 Acoustics
Configuration
Sound Power per
ISO 7779-C
6306 Open Pedestal
55 dB(A)
6306 Enclosed Pedestal
52 dB(A)
6312 Open Pedestal
60 dB(A)
6312 Enclosed Pedestal
57 dB(A)