TallyGenicom 6306 Maintenance Manual - page 69
Other manuals for 6306:
Quick Start Manual, Specifications, Operator's Manual, Operator's Manual, Installation Instructions Manual, Brochure, Specifications
of
175
Chapter 4. Removing and Replacing Components
63
4.9 Removing the Hammer Bank
1. Follow the instructions for removing the Operator Panel and Right-end cover.
2. Follow the instructions for removing the Ribbon Platform.
3. Release the Hammer Bank Ribbon Cable guides – squeeze tab at back edge then lift
gently (two places for the 6306 and four for the 6312).
Squeeze tab and lift
Remove Screws
4. Unplug the Hammer Bank Ribbon Cables (see above).
5. Loosen the screw holding the cable assembly strain relief clamp then slide the clamp
to the right and out of the hammer bank assembly.
Loosen screw –
Slide clamp to right