Summary of VEGABAR 82

  • Page 1

    Quick setup guide pressure transmitter with ceramic measuring cell vegabar 82 hart and accumulator pack document id: 46307.

  • Page 2: Contents

    2 contents vegabar 82 • hart and accumulator pack 46307-en-131125 contents 1 for your safety 1.1 authorised personnel ....................................................................................................... 3 1.2 appropriate use ...........................................................

  • Page 3: 1  For Your Safety

    3 1 for your safety vegabar 82 • hart and accumulator pack 46307-en-131125 1 for your safety 1.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the ...

  • Page 4

    4 1 for your safety vegabar 82 • hart and accumulator pack 46307-en-131125 electromagnetic compatibility instruments with plastic housing as well as those in four-wire or ex-d- ia version are designed for use in an industrial environment. Never- theless,electromagneticinterferencefromelectricalcondu...

  • Page 5: 2  Product Description

    5 2 product description vegabar 82 • hart and accumulator pack 46307-en-131125 2 product description 2.1 configuration thenameplatecontainsthemostimportantdataforidentificationand use of the instrument: 2 1 14 15 16 17 13 11 12 5 3 6 4 7 8 9 10 fig. 1: layout of the type label (example) 1 instrument...

  • Page 6

    6 2 product description vegabar 82 • hart and accumulator pack 46307-en-131125 • enter the serial number manually in the app.

  • Page 7: 3 Mounting

    7 3 mounting vegabar 82 • hart and accumulator pack 46307-en-131125 3 mounting 3.1 general instructions for use of the instrument protect your instrument against moisture penetration through the fol- lowing measures: • use the recommended cable (see chapter "connecting to power supply") • tighten th...

  • Page 8

    8 3 mounting vegabar 82 • hart and accumulator pack 46307-en-131125 1 2 3 6 6 6 6 6 5 4 fig.2:positionofthefilterelement-non-ex,ex-iaandex-d-iaversion 1 single chamber housing plastic, stainless steel (precision casting) 2 single chamber housing aluminium 3 single chamber housing, stainless steel el...

  • Page 9

    9 4 connecting to power supply vegabar 82 • hart and accumulator pack 46307-en-131125 4 connecting to power supply 4.1 connection of the battery charger we recommended charging the integrated accumulator completely beforesettinguptheinstrument.Youcanfindthechargingtimein chapter "technicaldata". The...

  • Page 10

    10 4 connecting to power supply vegabar 82 • hart and accumulator pack 46307-en-131125 2 4 3 5 0 5 1 6 2 7 3 8 4 9 modes 4 on/off 3 on/off 1h 1,2 off charge accu 5..9 auto cycle 1 2 + ( ) (-) 1 fig. 5: supply room 1 internal connection of the socket for the battery charger 2 mode switch 3 ledgreen,c...

  • Page 11: Module

    11 5 set up with the display and adjustment module vegabar 82 • hart and accumulator pack 46307-en-131125 5 set up with the display and adjustment module 5.1 insert display and adjustment module the display and adjustment module can be inserted into the sensor and removed any time. Four positions di...

  • Page 12

    12 5 set up with the display and adjustment module vegabar 82 • hart and accumulator pack 46307-en-131125 1 2 fig. 7: insertion of the display and adjustment module into the double chamber housing 1 in the electronics compartment 2 intheconnectioncompartment(withex-d-iaversionnotpossible) note: ifyo...

  • Page 13

    13 5 set up with the display and adjustment module vegabar 82 • hart and accumulator pack 46307-en-131125 3. Units in this menu item you determine the adjustment and temperature units of the instrument. Depending on the selected application in the menu item "application",differentadjustmentunitsarea...

  • Page 14

    14 5 set up with the display and adjustment module vegabar 82 • hart and accumulator pack 46307-en-131125 themainmenuisdividedintofivesectionswiththefollowingfunc- tions: setup:settings,e.G.,formeasurementloopname,application,units, positioncorrection,adjustment,signaloutput display:settings,e.G.,fo...

  • Page 15

    15 5 set up with the display and adjustment module vegabar 82 • hart and accumulator pack 46307-en-131125 menu item scaling 2 characteristicvaluesofthedifferential pressure transmitter volume/massflow current output 1 and 2 currentoutput-size current output - adjustment current output - mode current...

  • Page 16: 6 Supplement

    16 6 supplement vegabar 82 • hart and accumulator pack 46307-en-131125 6 supplement 6.1 technical data electromechanical data - version ip 66/ip 67 and ip 66/ip 68; 0.2 bar options of the cable entry Ʋ cable gland m20 x 1.5 Ʋ cable diameter (options) 5 … 9 mm (0.20 … 0.35 in) 6 … 12 mm (0.24 … 0.47 ...

  • Page 17

    17 6 supplement vegabar 82 • hart and accumulator pack 46307-en-131125 Ʋ -10° c (+14 °f) 50 %.

  • Page 18

    18 notes vegabar 82 • hart and accumulator pack 46307-en-131125.

  • Page 19

    19 notes vegabar 82 • hart and accumulator pack 46307-en-131125.

  • Page 20

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 46307-en-131 125 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subje...