Summary of VEGABAR 82

  • Page 1

    Quick setup guide pressure transmitter with ceramic measuring cell vegabar 82 4 … 20 ma/hart with sil qualification document id: 46308.

  • Page 2: Contents

    2 contents vegabar 82 • 4 … 20 ma/hart 46308-en-160212 contents 1 for your safety 1.1 authorised personnel ....................................................................................................... 3 1.2 appropriate use ......................................................................

  • Page 3: 1  For Your Safety

    3 1 for your safety vegabar 82 • 4 … 20 ma/hart 46308-en-160212 1 for your safety 1.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the ...

  • Page 4

    4 1 for your safety vegabar 82 • 4 … 20 ma/hart 46308-en-160212 1.6 sil qualification according to iec 61508 the safety integrity level (sil) of an electronic system is used to as- sess the reliability of integrated safety functions. For detailed specification of the safety requirements, multiple si...

  • Page 5: 2  Product Description

    5 2 product description vegabar 82 • 4 … 20 ma/hart 46308-en-160212 2 product description 2.1 configuration the type label contains the most important data for identification and use of the instrument: 2 1 13 14 15 12 10 11 5 3 6 4 7 8 9 fig. 1: layout of the type label (example) 1 instrument type 2...

  • Page 6: 3 Mounting

    6 3 mounting vegabar 82 • 4 … 20 ma/hart 46308-en-160212 3 mounting 3.1 general instructions for use of the instrument protect your instrument against moisture ingress through the following measures: • use the recommended cable (see chapter " connecting to power supply ") • tighten the cable gland •...

  • Page 7

    7 3 mounting vegabar 82 • 4 … 20 ma/hart 46308-en-160212 with the following instruments a blind plug is installed instead of the filter element: • instruments in protection ip 66/ip 68 (1 bar) - ventilation via capil- laries in non-detachable cable • instruments with absolute pressure.

  • Page 8

    8 4 connecting to power supply vegabar 82 • 4 … 20 ma/hart 46308-en-160212 4 connecting to power supply 4.1 connecting the voltage supply and signal output are connected via the spring- loaded terminals in the housing. Connection to the display and adjustment module or to the interface adapter is ca...

  • Page 9

    9 4 connecting to power supply vegabar 82 • 4 … 20 ma/hart 46308-en-160212 fig. 4: connection steps 5 and 6 - double chamber housing 6. Insert the wire ends into the terminals according to the wiring plan information: solid cores as well as flexible cores with wire end sleeves are insert - ed direct...

  • Page 10

    10 4 connecting to power supply vegabar 82 • 4 … 20 ma/hart 46308-en-160212 5 1 2 + ( ) (-) 6 7 8 4...20ma 2 3 4 1 fig. 5: electronics and terminal compartment, single chamber housing 1 voltage supply/signal output 2 for display and adjustment module or interface adapter 3 for external display and a...

  • Page 11: Module

    11 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma/hart 46308-en-160212 5 set up with the display and adjustment module 5.1 insert display and adjustment module the display and adjustment module can be inserted into the sensor and removed again at any time. You can choose any ...

  • Page 12

    12 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma/hart 46308-en-160212 1 2 fig. 8: installing the display and adjustment module in the double chamber housing 1 in the electronics compartment 2 in the terminal compartment note: if you intend to retrofit the instrument with a d...

  • Page 13

    13 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma/hart 46308-en-160212 change parameters you can find a description below the respective parameter. Lock adjustment and verify modified parameters you can find a description below the parameter " setup - lock adjust- ment ". 1. ...

  • Page 14

    14 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma/hart 46308-en-160212 2 1 100% 0% 5 m (196.9 ") fig. 9: parameter adjustment example "min./max. Adjustment, level measure- ment" 1 min. Level = 0 % corresponds to 0.0 mbar 2 max. Level = 100 % corresponds to 490.5 mbar if these...

  • Page 15

    15 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma/hart 46308-en-160212 menu - setup menu item parameter default setting measurement loop name sensor application (sil) application level slave for elec- tronic differential pressure deactivated units unit of measure- ment mbar (...

  • Page 16

    16 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma/hart 46308-en-160212 menu - diagnosis menu item parameter default setting sensor status - peak value pressure actual measured value temperature actual temperature values from meas- uring cell, electronics simulation pressure p...

  • Page 17: 6 Supplement

    17 6 supplement vegabar 82 • 4 … 20 ma/hart 46308-en-160212 6 supplement 6.1 technical data electromechanical data - version ip 66/ip 67 and ip 66/ip 68; 0.2 bar cable entry Ʋ m20 x 1.5 1 x cable gland m20 x 1.5 (cable: ø 6 … 12 mm), 1 x blind plug m20 x 1.5 Ʋ ½ npt 1 x blind plug npt, 1 x closing c...

  • Page 18

    18 notes vegabar 82 • 4 … 20 ma/hart 46308-en-160212.

  • Page 19

    19 notes vegabar 82 • 4 … 20 ma/hart 46308-en-160212.

  • Page 20

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 46308-en-160212 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subjec...