Summary of VEGABAR 82

  • Page 1

    Quick setup guide pressure transmitter with ceramic measuring cell vegabar 82 4 … 20 ma document id: 46305.

  • Page 2: Contents

    2 contents vegabar 82 • 4 … 20 ma 46305-en-131125 contents 1 for your safety 1.1 authorised personnel ....................................................................................................... 3 1.2 appropriate use ...........................................................................

  • Page 3: 1  For Your Safety

    3 1 for your safety vegabar 82 • 4 … 20 ma 46305-en-131125 1 for your safety 1.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the requi...

  • Page 4

    4 1 for your safety vegabar 82 • 4 … 20 ma 46305-en-131125 radiatedemissionsmustbetakenintoaccount,asisusualwithclass a instruments according to en 61326-1. If the instrument is used in adifferentenvironment,theelectromagneticcompatibilitytoother instruments must be ensured by suitable measures. 1.6...

  • Page 5: 2  Product Description

    5 2 product description vegabar 82 • 4 … 20 ma 46305-en-131125 2 product description 2.1 configuration thenameplatecontainsthemostimportantdataforidentificationand use of the instrument: 2 1 14 15 16 17 13 11 12 5 3 6 4 7 8 9 10 fig. 1: layout of the type label (example) 1 instrument type 2 product ...

  • Page 6

    6 2 product description vegabar 82 • 4 … 20 ma 46305-en-131125 • enter the serial number manually in the app.

  • Page 7: 3  Mounting

    7 3 mounting vegabar 82 • 4 … 20 ma 46305-en-131125 3 mounting 3.1 general instructions for use of the instrument protect your instrument against moisture penetration through the fol- lowing measures: • use the recommended cable (see chapter "connecting to power supply") • tighten the cable gland • ...

  • Page 8

    8 4 connecting to power supply vegabar 82 • 4 … 20 ma 46305-en-131125 4 connecting to power supply 4.1 connecting the voltage supply and signal output are connected via the spring- loaded terminals in the housing. Connection to the display and adjustment module or to the interface adapter is carried...

  • Page 9

    9 4 connecting to power supply vegabar 82 • 4 … 20 ma 46305-en-131125 7. Check the hold of the wires in the terminals by lightly pulling on them 8. Connectthescreentotheinternalgroundterminal,connectthe outer ground terminal to potential equalisation 9. Tighten the compression nut of the cable entry...

  • Page 10: Module

    10 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma 46305-en-131125 5 set up with the display and adjustment module 5.1 insert display and adjustment module the display and adjustment module can be inserted into the sensor and removed any time. Four positions displaced by 90° c...

  • Page 11

    11 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma 46305-en-131125 carry out the following steps in the below sequence. Youcanfind"extendedadjustment" in the next sub-chapter. 1. Measurement loop name inthefirstmenuitemyouassignasuitablemeasurementloopname. Permitted are names...

  • Page 12

    12 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma 46305-en-131125 6. Min. Adjustment in this menu item you carry out the min. Adjustment for level enter the percentage value and the corresponding value for the min. Level. Thequicksetupisfinished. 5.3 parameter adjustment - ex...

  • Page 13

    13 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma 46305-en-131125 setup menu item measurement loop name application units unit of measurement temperature unit position correction adjustment min. Adjustment max. Adjustment damping integration time linearization linearizationty...

  • Page 14

    14 5 set up with the display and adjustment module vegabar 82 • 4 … 20 ma 46305-en-131125 additional adjustments menu item pin date/time copy instrument settings special parameters.

  • Page 15: 6  Supplement

    15 6 supplement vegabar 82 • 4 … 20 ma 46305-en-131125 6 supplement 6.1 technical data electromechanical data - version ip 66/ip 67 and ip 66/ip 68; 0.2 bar options of the cable entry Ʋ cable gland m20 x 1.5 Ʋ cable diameter (options) 5 … 9 mm (0.20 … 0.35 in) 6 … 12 mm (0.24 … 0.47 in) 10 … 14 mm (...

  • Page 16

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 46305-en-131 125 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subje...