Verint Nextiva S1100w User Manual - page 86
H: Motion Track
70
Verint Video Solutions
2. Start the ManagerNET application.
The first time you run the application, the connection table is empty.
3. Right-click anywhere in the connection table, then choose Add Entry.
The Add Entry window appears.
4. In the Module Description box, enter a meaningful free-format text identifying the
DVMD module.
5. In the Channel ID box, select a number for the DVMD module. In a large system, you
should provide a unique value to each module to easily distinguish it from the others.
The Channel ID value is displayed under the CameraID column in the connection table.
6. Set the communication type to Network (as opposed to a local connection).
7. In the Type box, select UDPLink.
8. In the IP Address box, enter the IP address of the S1100w-MT device.
9. In the Port Numbers box, enter
5005
(the same value as in the Remote Port and Local
Port parameters in the CLI, as illustrated on page 69).
10. In the Module Address box, ensure that the value is FF0.