This tab allows you to specify when a target will generate an alarm.
Target Elimination—Two settings relative to the target velocity:
Maximum Velocity—The highest velocity limit for a target to be considered valid.
This feature reduces nuisance alarms from high-speed birds and bugs. The range of
values is 0–40.
Minimum Velocity—The lowest velocity limit for a target to be considered valid. This
feature reduces nuisance alarms from low-speed targets such as flashing neon
signs. The range of values is 0–40.
Luma Limit—Two settings to differentiate targets based on luma values. You use luma
values with thermal or infrared cameras to isolate targets above or below a certain
temperature, or within a temperature range:
Minimum Luma—The minimum setting to differentiate targets in thermal cameras
using the hot black setting. The range of values is 0–255.
Maximum Luma —The minimum setting to differentiate targets in thermal cameras
using the hot white setting. The range of values is 0–255.
Direction Elimination—To direct the DVMD module to ignore targets moving in a specific
direction.