Machine Setup
LTV
4.3
Ground Connection
Location
A ground connection (a) is located on the trailer frame.
Function
This ground connection is used for electrically grounding the Light Tower when
necessary to comply with the National Electrical Code and other federal, state, and
local regulations. For grounding requirements in your area, consult with a qualified
electrician, electrical inspector, or local agency having jurisdiction over electrical
compliance.
■ If the Light Tower is used at a construction site, there may be additional
regulations which must be observed.
Internal
grounding
■ The exposed, conductive, noncurrent-carrying components that could become
energized (e.g., engine, generator housing, control panel, and trailer) are
bonded (connected to the machine’s frame.
■ The grounding wires of the machine’s power outputs (receptacles) are bonded
(connected) to the machine’s frame.
■ The neutral of the generator stator winding is bonded (connected) to the
machine’s frame.
wc_gr013762
a