First Time Power-Up and Start-Up
5.2.2 Basic Application Menu
Step
Action/Display Indication
Step
Action/Display Indication
1
2
Monitoring mode.
Press the
ENTER/MENU key to get into
the first level of the programming mode.
The
PARAM group is selected, press
the
or
keys to select the BASIC
group.
3
4
Press
ENTER/MENU when the group is
selected.
In this moment the Basic Application
routine is initiated. If necessary, change
“P0100 – Acceleration Time” parameter.
Press the
or
key to the next
parameter.
5
6
If n e c e s s a r y, c h a n g e
“ P 0 1 0 1 –
Deceleration Time”.
Press the
or
key to the next
parameter.
If necessary, change
“P0133 – Minimum
Speed” parameter.
Press the
or
key to the next
parameter.
7
8
If necessary, change
“P0134 – Maximum
Speed” parameter.
Press the
or
key to the next
parameter.
If necessary, change
“P0135 – Max.
Output Current” parameter.
Press the
or
key to the next
parameter.
9
10
If necessary, change
“P0136 – Manual
Torque Boost” parameter.
Press the
or
key to the next
parameter.
Press the
BACK/ESC key to end the Basic
Application routine.
Press the
BACK/ESC again to go back to
the monitoring mode.
Figure 5.2: Basic application group