Performance Curves—Flush Mount Models
Minimum Separation Distance Between Target and Background for: Uniform and Non-Uniform Targets
110 mm Models
310 mm Models
Minimum Separation T
arget to Background
(mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
2
4
6
8
10
12
14
16
18
20
22
0
25
50
75
100
125
150
175
200
225
250
275
300
325
Matte targets with uniform
reflectivity: 6% to 90%
Target
Switch Point
Distance
Background
X
Y
Matte targets with a non-uniform
reflectivity: 6% to 90%
Minimum Separation T
arget to Background
(mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0
25
35
50
75
100
125
Matte targets with a non-uniform
reflectivity: 6% to 90%
Matte targets with uniform
reflectivity: 6% to 90%
Flush Mount Models
110
35
310
610
610 mm Models
Minimum Separation T
arget to Background
(mm)
Dimension Y
Distance to Target (mm)
Dimension X
0
2
4
6
8
10
12
14
16
18
20
22
0
100
35
200
300
400
500
600
Matte targets with uniform
reflectivity: 6% to 90%
Matte targets with a non-uniform
reflectivity: 6% to 90%
Figure 15. Minimum Object Separation Distance (90% to 6% reflectance)
Dual Mode Reference Surface Considerations
Optimize reliable detection by applying these principals when selecting your reference surface, positioning your sensor
relative to the reference surface, and presenting your target. The robust detection capabilities of the Q4X allows successful
detection even under non-ideal conditions in many cases. Typical reference surfaces are metal machine frames, conveyor
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
P/N 190073 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
11