Banner Q4X Quick start manual - page 9
Excess Gain using a 90% White Card—100/110/300/310 mm Models
Table 6:
Excess Gain (
Excess Gain
1
)
Response Speed (ms)
· at 25 mm (100/300 mm models)
· at 35 mm (110/310 mm models)
· at 100 mm (100/300 mm models)
· at 110 mm (110/310 mm models)
· at 300 mm (100/300 mm models)
· at 310 mm (110/310 mm models)
1.5
200
100
20
3
200
100
20
10
1000 (500)
500 (250)
100 (50)
25
2500 (1000)
1250 (500)
250 (100)
50
5000 (2500)
2500 (1250)
500 (250)
Excess Gain using a 90% White Card—600/610 mm Models
Table 7:
Excess Gain (
Excess Gain
2
)
Response
Speed (ms)
· at 25 mm (600 mm models)
· at 35 mm (610 mm models)
· at 100 mm (600 mm models)
· at 110 mm (610 mm models)
· at 300 mm (600 mm models)
· at 310 mm (610 mm models)
· at 600 mm (600 mm models)
· at 610 mm (610 mm models)
2
280
110
25
6
5
280
110
25
6
15
1000 (360)
400 (150)
80 (30)
20 (7)
25
2000 (1000)
800 (400)
160 (80)
40 (20)
50
4000 (2000)
1600 (800)
320 (160)
80 (40)
Environmental Rating
IEC IP67 per IEC60529
IEC IP68 per IEC60529
IEC IP69K per DIN40050-9
Vibration
MIL-STD-202G, Method 201A (10 Hz to 60 Hz, 0.06 inch (1.52 mm)
double amplitude, 2 hours each along X, Y and Z axes), with sensor
operating
Shock
MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y and Z axes,
18 total shocks), with sensor operating
Operating Conditions
−
10 °C to +50 °C (+14 °F to +122 °F)
35% to 95% relative humidity
Storage Temperature
–25 °C to +75 °C (
−
13 °F to +167 °F)
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads
For additional product support, go to
www.bannerengineering.com
.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
UL Environmental Rating: Type 1
chemical compatibility certified
ECOLAB is a registered trademark of Ecolab USA Inc. All rights
reserved.
1
•
excess gain available in 10 ms, 25 ms, and 50 ms response speeds only
•
excess gain provides increased noise immunity
2
•
excess gain available in 15 ms response speed only
•
excess gain provides increased noise immunity
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
P/N 190073 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
9