KAL-FIRE ECO-prestige 105-59 Installation instructions manual - page 166
Manual is about: Balanced-flue gas system
Fairo(-hybrid) ECO-prestige
of
184
62
15.2
Unblocking the fire after a code ‘A’ failure (e.g. 08A)
Press the
button around 5 times, until the ‘A’ code disappears. A
new ignition attempt can then be tried. (Hold down the
button
until ‘OK’ begins to flash at the top left of the screen.)
15.3
Unblocking the fire after a code ‘F’ failure (e.g. 08F)
After a period of 24 hours, the burner will unlock automatically. If the power to the
appliance is turned off, this safety measure will not be triggered. This is strictly forbidden
and could put your safety at risk!