KAL-FIRE ECO-prestige 105-59 Installation instructions manual - page 82
82
38.2
Overview of country specifications
38.3
Special installation instructions for gas type ELL G25 with 20 mbar prepressure, capacity <11 kW (only for Fairo ECO
Prestige 105/79)
For gas type ELL G25 with a prepressure of 20 mbar, the following steps should be taken:
Remove the restrictor plates (page 13).
Check that both ceiling boards have been installed.
.
Ceiling boards
Change the TP-setting using the configuration menu:
1
Press
P
for 40 seconds until TCOM displays on the screen.
Note: After 10 seconds, the hour starts to flash on the top left of the screen. Hold down the
P
button
until TCOM displays on the screen.
Country overview
AT
BE
CH
CZ
DE
DK
ES
FI
FR
HU
GB
GR
IE
IT
LU
NL
NO
PT
PL
I2H
G20
20mbar
√
√
√
√
√
√
√
√
√
√
√
√
√
I2E
G20
20mbar
√
√
√
I2E+
G25
G20
25mbar
20mbar
√
√
√
√
I2L
G25
25mbar
√
I2ELL
G25
G20
20mbar
20mbar
√
√
I3+
G30
G31
28-30mbar
37 mbar
√
√
√
√
√
√
√
√
√
√
I3B/P
G30
28-30mbar
√
√
√
√
√
√
√
√
√
√
I3B/P
G30
50mbar
√
√
√
√