KAL-FIRE ECO-prestige 105-59 Installation instructions manual - page 83
Manual is about: Balanced-flue gas system
Fairo(-hybrid) ECO-prestige
of
184
83
2
Press
P
and
simultaneously.
3
FH
displays on the screen. Press P and
simultaneously again.
4
TP
displays on the screen. Press the left
or right
button to select the correct parameter (see
the table below).
5
Select the desired parameter using
+
or
-
. Wait until the value stops flashing. When it stops flashing, the value is confirmed.
Press
to exit the menu.
Parameter
Description
Burner pressure
TP 01
Minimum burner pressure
9.9 mbar
TP 02
Maximum burner pressure
13.6 mbar