3.3.4 Through-mount version water cooler IP54
87
403
31,5
32
8
520
21
212
72
285
7,5
16 x 7,5
101
(5 x 101) = 505
270 90
70
L2
L3
+
-
R
U
V
480
(5 x 101) = 505
101
11,5
244
90
270
(135)
M6
ST
FS
OPT DEV NET VCC
ST ST
Housing size
6
Weight
17.3 kg
Figure 7:
Dimensions through-mount version water cooler IP54
IP54 zone: Heat sink underneath the mounting plate. For proper installation,
the enclosed seal (60F6T45-0002) must be installed between heat sink and
housing (e.g. cabinet wall). The tightness must be checked after the installa-
tion. If properly installed, the separation to the housing corresponds to degree
of protection IP54.
IP20 zone (device above the mounting plate, power connections excluded).
This part is intended for the installation in a suitable housing for the required
degree of protection (e.g. control cabinet).
UL:UnitheatsinkisclassifiedasNEMAtype1.
41