74
Temperature control
The cooling can be switched on by means of a pneumatic valve or a solenoid valve,
which is connected uptream by a relay. The valves for temperature control must be used
intheflowlineofthecoolingcircuitinordertoavoidpressuresurges.Allconventional
valves can be used. Make sure that the valves are working properly and do not clamp.
ATTENTION
Destruction of the heat sink at storage of water-cooled devices!
Observe the following points when storing water-cooled devices
► Completely empty the cooling circuit
► Blow out the cooling circuit with compressed air
67
cOOLANT TeMPerATUre AND MOISTUre cONDeNSATION