KEB COMBIVERT F6 Instructions For Use Manual - Attention
TA1
TA2
+
KTY84
KTY sensors are polarized semiconductors and must be operated in
forward direction! To this connect the anode to TA1 and the cathode
to TA2! Non-observance leads to incorrect measurements in the
upper temperature range. A protection of the motor winding is then
no longer guaranteed.
Figure 24: Connection of a KTY sensor
ATTENTION
No protection of the motor winding in case of wrong connection.
► Operate KTY sensors in forward direction.
► KTY sensors may not be combined with other detections.
NOTE
„Basic insulation“ against SELV voltage of the control. A system voltage (Phase – PE) of
300Visdefined.Consequently,theconnectedsensorsalsomusthavea„basicinsula-
tion“ to the mains potential (e.g. motor winding)!
More information about the wiring of the temperature monitoring and the brake
control are described in the respective control unit manual.