Setting up the Swift
Grinder S/D
Regulation of single and
double doses: to establish
the doses on this specific
grinderitisnecessarytoread
through the procedures for
the standard Swift under
the section “Regulation of
quantity for dosing” as well
as follow these procedures.
BOtH MOtORS AND
HOPPERS CAN DELiVER
SiNGLE AND
DOUBLE DOSES
Itismandatorytoproceedas
follows:
Double dose:
1)Turn off the machine and
remove the front tower
cover to access to the
screwsthatfixtheshaftof
the impeller.
2)Set the quantity of the
coffeinthefilterasonthe
standard Swift model.
(see image A)
3) Adjust the grind (double):
adjustthegrindtoextract
60ml in 25 seconds.
4) Set the height of the
cylindrical
ring:
the
cylindricalringnexttothe
impeller should be at a
height that allows to obtain
a coffee puck surface that
iscompletelyeven.
NOtE: The regulation of the
height of the cylindrical ring
(moveable part or tamper)
is carried out by rotating
the part clockwise to lift the
ring and rotating it counter
clockwisetolower.
The cylindrical ring is held
inplacebytwobrassscrews
(see image b) so that the
vibrations caused by the
rotation of the impellers do
notalteritsposition.
Remove the two screws and
manually rotate the part,
graspingitfromthebottom.
the distance between the
impeller and the cylindrical
ringcanvaryfromaminimum
of 4 mm to 6 mm, a length
that permits to obtain a
perfectly even coffee puck
(see picture below).
Raisering(counterclockwise)
Lowerring(clockwise)