Single dose:
Thequantityofcoffeeforthe
single dose is regulated by
time.
By turning the screw at the
left blue trimmer positioned
atthebackofthekeypaditis
possible to vary the grinding
time.
Turningthescrewsclockwise,
thetimeincreases,increasing
the dose.
turning them counter
clockwise,
the
time
decreases,decreasing the
dose.
this model of the grinder
supplies a double dose that
can be set
between 15 and 17 gr and a
single dose that can be set
between 7,5 and 8,5 gr.
1)Beforesettingup,testthe
singledose:
a) if extraction timing of 30
ml of espresso is less than
25 seconds, increase gram
dose by rotating trimmer
clockwise.
b) if extraction timing of 30
ml of espresso is more than
25 seconds, decrease gram
dose by rotating trimmer
counterclockwise.