Oki OKIPAGE18n User Manual - page 124
E-124
|
OKIPAGE 18/24DX
Interface
IEEE 1284 Parallel Interface
Parallel cable requirements:
•
Cable must be shielded with twisted pair conductors, and
must be UL and CSA approved
•
Maximum length for bi-directional cable is 6 feet (1.8
meters). For lengths greater than 6 feet, use a cable
marked IEEE 1284-compliant.
•
Printer connector is an IEEE 1284-B receptacle (36 pins,
0.085" center line)
•
Port supports bi-directional IEEE 1284 communications
(compatibility, nibble, and ECP modes)
Bi-Directional Parallel Mode
If you are using the Status Monitor software, which provides
on-line feedback of the printer status, BI-DIRECTION must
be set to ENABLE (default) in the Level-2 printer main menu
(see the Printer Control chapter).
The recommended cable length for bi-directional
communications is 6 ft. (1.8 meters). The standard parallel
cables available at computer stores should work fine. For
extended distances, higher quality IEEE 1284-compliant
cables are available.