Oki OKIPAGE18n User Manual - page 126
E-126
|
OKIPAGE 18/24DX
RS232-C Serial Interface
Serial cable requirements:
•
Cable must be shielded with twisted pair conductors, and
must be UL and CSA approved
•
Maximum length for serial cable is 6 feet (1.8 meters).
•
Printer connector is Type 17LE-13250-27 (D4CC)
receptacle (25 pins)
Serial Mode
The serial interface settings on your printer and computer
must match. To change printer settings, enter the Level 2
menu (press ON LINE to place the printer off-line, then press
MENU 1/Menu 2 for 2 seconds, until PRINT MODE appears)
and select the RS232C SERIAL category. Set FLOW
CONTROL, BAUD RATE, DATA BITS, PARITY, and MIN.
BUSY to match the settings on your computer. Following are
the printer default settings for these parameters:
FLOW CONTROL
DTR HI POLARITY
BAUD RATE
9600 BAUD
DATA BITS
8 BITS
PARITY
NONE
MIN. BUSY
200 mSECONDS