P&E Microcomputer Systems XPC560S EVB User Manual - page 50
46
xPC560S EVB User Manual
J26 – VDDA Voltage Selection
Sets the voltage level on the MPC560xS “VDD_ADC” power pin.
5.3
System Clock Configuration
The xPC560S Mini-Modules support the usage of crystal clock sources as
well as external clock sources.
J10 – Crystal clock source enable
Both of the jumpers below need to be installed to enable the crystal clock
source.
1+2 (default)
MPC560xS “VDD_IO_A” and “VDD_IO_E” are
powered by 5V (J14 must be ON)
2+3
MPC560xS “VDD_IO_A” and “VDD_IO_E” are
powered by 3.3V (J18 must be ON)
Jumper Setting
Effect
1+2 (default)
MPC560xS “VDD_ADC” is powered by 5V (J14 must
be ON)
2+3
MPC560xS “VDD_ADC” is powered by 3.3V (J18 must
be ON)
Jumper Setting
Effect
1+2 (default)
The MPC560xS “EXTAL” signal is connected to the
crystal clock source on the xPC560S Mini‐Module