WEG SCA06 User Manual - page 20
3
Installation and Connection
3-2 | SCA06
If the mounting is inside a panel, provide proper ventilation so that the internal temperature remains within the
allowed range for the operating conditions of the servo drive.
The power dissipated by the servo drive at rated condition is specified in
Table 9.1 on page 9-1
.
ATTENTION!
Provide independent conduits or gutters for the physical separation of signal, control, and power
cables (refer to
section 3.2 ELECTRICAL INSTALLATION on page 3-6
).
C1
B1
D1
A1
A2
A3
C1
B1
D1
A1
A2
A3
Model
A1
A2
A3
B1
C1
D1
Torque
(*)
mm
(in)
mm
(in)
mm
(in)
mm
(in)
mm
(in)
M
N.m
(lbf.in)
Frame size B
200
247
253
75
206.7
M5
5
(7.87)
(9.72)
(9.96)
(2.95)
(8.14)
(44.2)
Frame size C
242
288
294
75
206.7
M5
5
(9.53)
(11.34)
(11.57)
(2.95)
(8.14)
(44.2)
Tolerance of the dimensions: ±1 mm (±0.039 in).
(*) Torque recommended to fix the servo drive (valid for D1).
(a) Frame sizes B and C