WEG SCA06 User Manual - page 52
6
Energizing and Start of Operation
6-6 | SCA06
Sequence
Action / Result
Indication on the Display
8
Press the key
to increase the speed. The
servomotor must be spinning according to the
programmed speed.
9
Program the desired speed and press the key
to save the content.
10
Press the key
until you reach parameter
P00099.
11
Press the key
to enter the content of
parameter P00099.
12
Press the key
. Then the motor will stop,
that is, it will be disabled. Whenever P00099
is enabled, the motor will spin at the speed
programmed in P00121.
Figure 6.3: Sequence to enable the servomotor
6.2.2 Example 2: Operation in Speed Mode - Using Accessory EAN 1 - With Position Control Done by
External Device (CNC, for example)
Parameters to be set:
Set password
P00000 = 5
Program motor
P00385 = according to available model
Program operating mode
P00202 = 2
Program DI1 for enabling
P00300 = 1
Program Error via DO1
P00280 = 6
Program speed reference via AI2