WEG SCA06 User Manual - page 57
7
Troubleshooting and Maintenance
SCA06 | 7-3
1 – CR2032-type battery
Figure 7.1: Battery location7
Procedure for replacement:
1. Turn off the control and the power of the servo drive
2. Remove the accessory or cover of Slot 2 as shown in
Figure 7.1 on page 7-3
3. Turn on the control of the SCA06 (power up the 24 V supply)
4. Remove the battery and put a new one
5. Turn off the control
6. Put the accessory or cover back on Slot 2
ATTENTION!
The battery must be installed with the control circuit powered up.
ATTENTION!
When using resources that use the battery (real time clock and retentive memory), it is advisable to
activate the low battery alarm (refer to the programming manual).
NOTE
At the end of the useful life, do not dispose of the battery in common garbage, but in a proper place
for batteries.