GECON LITE PLUS in control panel mode
New feature of Gecon lite is a functionality of a small independent control panel. You can connect Dallas key
reader supporting up to 8 keys that serve for arming and disarming. Control panel also contains buzzer and control
LED diodes. The connection scheme is following:
You will need to power the device from external backed up power source with nominal voltage of 12V or use the
back-up power supply provided by manufacturer.
You can activate control panel mode by sending the command:
IBUT=ON
GECON LITE PLUS is now set to the control panel mode. Subsequently you will need to programm iButton (Dallas
Keys) if they were not already programmed.
WARNING !!!
Delay of inputs is not functioning in this mode and has to be set to zero level.
Note: Function of alarm filtering affects only calls, it does not affect the siren output.
If the input is set as status or permanent, it reacts both in armed and disarmed state. (please see below for input
types settings)