Zadako GECON LITE PLUS Installation Manual - page 13
13
Turning off the „control panel mode“
To turn off the control panel mode and return to caller mode, send SMS command in following form:
IBUT=OFF
Note: Programmed DALLAS keys will remain in the memory, the memory for the numbers is same for the caller
and control panel mode.
To delete and program Dallas keys please use following commands:
To delete all programmed Dallas keys: command IBDA
To program Dallas keys fo free positions: command IBRN
After receiving above command, buzzer will beep and LED diode will blink with high frequency. In this moment you
can add codes of additional keys to memory of Gecon lite plus. You can do it by attaching the keys. Programming
(learning of the particular keys) is signalized by double beep of the buzzer. If you attached the key twice, long beep
will sound. It is possible to program (learn) up to 8 Dallas keys. The learning regime will end after one minute, or by
attaching of 8 Dallas keys.
If the programming was already performed, new programming will not erase previously programmed keys, it will
only add new ones.
Setting of input type:
Digital inputs in control panel mode can be set in several ways:
A – Delayed loop – the breach will not trigger alarm if a Dallas key is attached to the control panel in entrance
delay
I – Instant loop– the breach will trigger alarm immediately in armed status.
P – Permanent loop – the breach will trigger alarm both in armed and disarmed status.
T – Status loop– input is active both in armed and disarmed status and sends SMS by every change of status
You can set loop type by command IN by putting = character after IN and defining each of 4 inputs.
The sequence of symbols A,I,P,T after = defines also the sequence of set inputs. That means that first letter
defines first input, second letter second input and so on.
Example:
abcd IN=AIPT - 1= Delayed 2= Instant 3= Permanent 4= Status
abcd IN=AIIP - 1= Delayed 2= Instant 3= Instant 4= Permanent
Setting of exit delay:
This setting is done by command abcd EXIT=10
This command will set exit delay to 10 seconds. Allowed range is from 3 to 240 seconds.
Setting of entrance delay:
This setting is done by command abcd ENTRY=20
This command will set entrance delay to 20 seconds. Allowed range is from 3 to 240 seconds.