Arming – disarming by SMS command:
Arming and disarming can be also performed by SMS command in form abcd ARM and abcd DISARM.
Detection of validity and value of credit on the prepaid SIM cards via SMS:
This command will return validity of SIM card and remaining credit on prepaid SIM cards
abcd CREDIT phone number
Example:
abcd CREDIT *111# on T-mobile Slovakia SIMs
abcd CREDIT *100*# on O2 Slovakia SIMs
Note: please check with your SIM card provider if this function is supported and for local settings.
Programming via SW ver. 3.1 and higher
Programming procedure:
1. Be sure that PIN code protection is disabled on the SIM card
2. Insert the SIM card to the GECON LITE PLUS SIM holder.
3. Connect power supply to GECON LITE PLUS.
4. Wait till GECON LITE PLUS registers into the cellular network. This is signaled by short flashing of status
LED diodes.
5. Connect the programming cable to RS 232 connector and PC.
6. Run the configuration software, press Download button.
7. Configure the device according your requirements and confirm by clicking to Upload button.
8. If you would like to save the settings, you can do it by pressing Save and saving the configuration file to
your hard drive.
Note:
The software uses auto detection of port, that means that it will automatically detect Gecon lite plus, there is no
need for any special settings.
It is recommended to use test tablo to check if all settings are correct. The tablo enable visualization of Gecon lite
plus activities without real calls and SMS sending, which could save costs, make settings check faster and more
efficient and detects eventual wrong settings.
In case of configuration of on-line print function via software, the changes will only appear after disconnection of
programming cable and Gecon lite plus restart (connection-disconnection of power supply).