Zadako GECON LITE PLUS Installation Manual - page 6
6
Phone number settings:
GECON Plus can send reports to 4 phone numbers. Numbers are set following:
T1=090311111
T2=
T3=
T4=65464464
To delete a number from Gecon, use the command with # character instead of number.
Example:
Setup of first phone number
abcd T1=0901777555
Delete of first number
abcd T1=#
By inserting a phone number, all events from all inputs are reported to all numbers.
You can change this by function of report routing. (See Additional functions)
Input logic:
Digital input can have two states – open and close. Therefore it is necessary to determine which state is normal,
and which is a reason for triggering of alarm. Two states are commonly used with security devices – NO and NC.
NO - normally open
NC - normally closed
The inputs can be set by SMS following:
O - normally open
C - normally closed
Example:
LOG=OCCO
Input 1 is normally open NO
Input 2 is normally closed NC
Input 3 is normally closed NC
Input 4 is normally open NO
Setup of input type
Digital inputs can have two functions- to report alarm and information about trouble/recovery.
Alarm is reported by SMS and voice call on predefined numbers. Recovery after alarm is not reported.
Trouble/recovery from the trouble is reported by SMS.
A- alarm input
T- trouble input
Example:
IN=AAAA
All inputs are alarm inputs..
IN=ATTT
First input is alarm input and remaining three are trouble inputs.